Reasons and solutions for p0 issue in air conditioner

When this happens, it is usually because of the power supply voltage Caused by instability, the air conditioner should not be used at this time, otherwise the internal parts of the air conditioner will be damaged.

The solution is to install a voltage regulator so that the air conditioner can obtain a normal and stable voltage. Unstable power supply voltage is usually caused by poor quality sockets, wires, etc., and a fault code appears. Replacing the socket may also solve the problem.

Different air conditioner brands have flooded the market, and people can choose from a variety of air conditioners. Air conditioner failures are very common. Now let's talk about the specific content of P0 from the air conditioner, and see what is causing it and how to solve it. - DayDayNews

Detailed consultation: 400-0620-061

How to collect fluorine when moving the air conditioner in winter

In winter, if the air conditioner needs to be moved, it needs to collect fluorine. You can follow the following steps.

1. Check the outdoor unit of the air conditioner and locate the two Freon pipes. The high-pressure valve is connected to the thin pipe, and the low-pressure valve is connected to the thick pipe.

2. Use adjustable wrench to remove the sealing nuts of the two valves.

3. Use an Allen wrench to tighten the nut in the thin tube.

4. Use a screwdriver to remove the back cover of the air conditioner outdoor unit.

5. Soak the temperature control probe in hot water, so that you can turn on the cooling mode.

Different air conditioner brands have flooded the market, and people can choose from a variety of air conditioners. Air conditioner failures are very common. Now let's talk about the specific content of P0 from the air conditioner, and see what is causing it and how to solve it. - DayDayNews

Detailed consultation: 400-0620-061

6. Use the remote control to turn on the air conditioner and adjust it to the cooling mode. Try to set the temperature as low as possible to ensure that the compressor can operate.

7. After running in cooling mode for 2 minutes. Tighten the nut in the thick tube of the outdoor unit with an Allen wrench. At this time, all the fluorine will be absorbed into the outdoor unit.

8. Use an adjustable wrench to install and tighten the sealing nuts of the two valves. In this way, the work of collecting fluorine in winter is completed.

The above is the content related to the P0 produced by the air conditioner. The air conditioner is an important large appliance in the home. If the air conditioner is running normally, your life will feel smoother.