gas detector , I believe everyone is no longer unfamiliar with it. Everyone should have some understanding of the application of gas detectors. Today, the editor of Dongriyingn will introduce to you an important place that will be ignored, and products such as gas detectors are also needed. Let’s take a look together:

University laboratories have various gas storage conditions due to their experimental environment characteristics, and some toxic and harmful gases will also appear during the experiment. If the experimenter fails to operate according to the specifications, it will cause leakage and poisoning incidents and cause bad situations. Therefore, it is also more important to set up a corresponding toxic and harmful gas detector in a laboratory environment. The toxic and harmful gas detector installed in the environment can detect possible changes in the concentration of toxic and harmful gases. How should it be set up? Let’s take a look together:


  1. The detector should be installed in a place without impact, vibration, strong electromagnetic field interference, and easy to inspect. The clearance between the detector installation location and the surrounding process pipelines or equipment should not be less than 0.5m.
 

 2. When detecting combustible gases or toxic gases heavier than air, the installation height of the detector should be 0.3m to 0.6m from the floor (or floor); when detecting combustible gases or toxic gases lighter than air, the installation height of the detector should be within 2.0m above the release source. When detecting combustible gases or toxic gases slightly heavier than air, the installation height of the detector should be 0.5m to 1.0m below the release source; when detecting combustible gases or toxic gases slightly lighter than air, the installation height of the detector should be 0.5m to 1.0m higher than the release source.
  

3. The installation height of the ambient oxygen detector should be 1.5m to 2.0m away from the floor or floor.
  

4. Linear combustible gas detectors should be installed in large space open environments, and the length of their detection area should not be greater than 100m.
  

or above are some of the applications and precautions of Dongri Yingneng gas detectors in university laboratories. Users in need can refer to them when purchasing.