When it comes to automatic fire alarm and linkage control system, most electrical personnel are probably familiar with it, but for some electrical beginners, there may be fog in the clouds.

When it comes to fire automatic alarm and linkage control system, most electrical personnel are probably familiar with it, but for some electrical beginners, there may be fog in the clouds. The automatic fire alarm and fire-fighting linkage control system consists of a trigger device, an alarm device, an alarm device, a linkage device and a power supply. The trigger device is an alarm triggering device, including two types: manual and automatic triggering devices. The manual trigger device is manual fire alarm button , and the automatic trigger device is fire detector . The alarm device is a device that receives or displays fire alarms. The fire alarm controller and fire display disk are both alarm devices.

Alarm device mainly alerts to remind the on-site personnel to pay attention that the alarm device has important sound, light or acousto-optical alarms. The linkage device is that after receiving the external fire alarm signal, the fire automatic alarm and fire protection linkage controller must start with some external equipment, such as starting the fire prevention and exhaust system, emergency lighting, fire protection roller shutter and other systems, and cutting off the non-fire power supply. Power supply is also an indispensable part of the system. Automatic fire alarm and fire protection linkage control systems generally use UPS power supply to power it.

In recent years, with the booming development of my country's fire protection industry and the rapid development of computers and modern communication technology, the automation and intelligence level of fire protection facilities has been continuously improved. Fire protection technology has realized automatic fire monitoring, automatic alarm process, fire equipment linkage control, etc. In the design of fire automatic alarm system and its fire protection linkage control system, different national policies, specifications, and regulations should be followed, and different fire automatic alarm and fire protection linkage control systems should be designed according to different situations to achieve safety, advancedness, efficiency and rationality. Today we will learn about the construction process, installation and wiring and difficult measures of automatic fire alarm and linkage control system.

(1) Construction process flow of fire automatic alarm and linkage control system:

(2) Wiring requirements for fire automatic alarm and linkage control system:

https://www. ml1 (3) Fire automatic alarm and linkage control system equipment installation:

html l29

(4) Automatic fire alarm and linkage control system debugging:

2

(5) Construction difficulties and corresponding measures of automatic fire alarm and linkage control system:

Learn more about electrical knowledge:

Comprehensive explanation: automatic fire alarm, fire linkage controller and fire fire extinguishing controller

Fire Control Room Setting Requirements

Fire Power and Domestic Power Supply and Distribution System and Fire Emergency Lighting System are detailed explanations, all of which are knowledge points! Favorite it,

What does it mean to remove non-fire power? What are the non-fire-fighting power supplies that need to be cut off during a fire?

How should the fire load and non-fire load grouping scheme of low-voltage distribution system be designed to be reasonable?

Several common problems in electrical fire protection design

What are the non-fire protection power supplies that should not be cut off immediately during fire?

Analysis of common quality problems such as power supply and distribution systems, fire equipment power distribution, lightning protection grounding, lighting, etc.

Analysis of the settings of fire power and security power for civil buildings