Accident 1: Faku County "2·1" elevator fell
On February 1, 2015, a special equipment accident occurred in a community in Faku County. During an inspection in the community, a security guard in the community used the elevator triangular key to open the elevator landing door for inspection. He fell into the elevator shaft through the hall door of a certain floor of a unit in Building 5 and died after being rescued by the hospital.
Accident 2: Heping District "7·15" Huayang Building elevator fell
On July 15, 2015, Huayang Building, No. 386 Qingnian Street, Heping District, No. 6 elevator car The car ran from the 27th floor to the 1st floor. When the car ran to about the 23rd floor, the elevator speed became faster and went down at an excessive speed. When the car approached the 1st floor, the safety gear acted and the car came to an emergency stop. The ceiling and lighting of the car decoration fell off. 12 passengers in the car went to the hospital for examination, and 2 of them underwent surgery.
Accident 3: Elevator accident at the "9·5" Hailed Building in Huanggu District
At around 4 a.m. on September 5, 2016, an elevator in Block B of Hailed Building, Changjiang Street, Huanggu District, Shenyang broke down. The elevator stopped between the sixth and seventh floors, and 7 people were trapped. Later, rescue personnel arrived at the scene. During the rescue process, a young man and woman escaped from the elevator and fell down. One person died on the spot, one person was sent to the hospital and died after rescue efforts failed, and the remaining five people escaped.

Today, elevators have long become an indispensable and important tool in our daily lives, but cases happening around us remind people all the time "Is your elevator safe?"
The pass rate of the random inspections was 99.09%

The Shenyang Municipal Quality Supervision Bureau announced the 2016 Shenyang Elevator Safety Supervision Spot Inspection Report on the 10th. The results showed that the pass rate of the randomly inspected elevators was 99.09%.

This shows that the overall safety performance of elevators in use in Shenyang is very good, but individual elevators still have safety hazards.
In this safety supervision and inspection work, a total of 2,317 elevators in 515 user units in the city were inspected, including 1,947 traction drive elevators, accounting for 84.03% of the total; and 370 escalators and moving walkways, accounting for 15.97% of the total.
More than half of the places where elevators are used in the random inspections are residential areas, and the remaining places are shopping malls, public transportation places, commercial office buildings, hospitals, schools, apartments, supermarkets, etc. Among the elevators that were randomly inspected, 2,296 were qualified for , with a pass rate of 99.09%, and 21 were unqualified, with a failure rate of 0.91%.
Among the 21 units that failed, the reasons for failure include incomplete usage data, the user neglecting to establish and save elevator files, data, the distance between the car and the shaft wall exceeds the standard, and some old elevators do not comply with the new national standards; the emergency alarm device fails, the lines are aging, or there are problems with installation and use.
List of unqualified elevators

"Calmness" in self-rescue is crucial for trapped elevators I don't know if you still remember, there was a classmate in Harbin who was trapped behind the elevator. While waiting for rescue, he finished all his homework in various subjects. He was called the "Calm Brother" of the elevator. In fact, if you are trapped in an elevator, you must not be anxious. Follow the safety knowledge to rescue yourself, and then call for help as much as possible.

It is definitely not possible for everyone to still do homework when trapped in an elevator, but self-rescue is a must. If you are trapped in an elevator, ringing the bell and other assistance is the key.

Press the alarm bell in the elevator immediately, or use the intercom to contact the manager. You can also call loudly or tap the elevator door intermittently. If your mobile phone has a signal, you can directly call the police for help. While waiting, do not take drastic actions and do not open the door on your own. Do not escape through the skylight. If the car door cannot be opened temporarily, professional rescuers should assist you. Only after the power is cut off can you escape through the skylight.
The elevator does not run. Calm down and try more

After the elevator door is closed, the elevator does not start running. You can first press the door opening button on the control panel to open the elevator, and then press the door closing button to close the elevator to see if the fault is resolved and the elevator continues to run. Repeat once or twice, or use a hand push to help close the door. If that doesn't work, you have to press the door open button to open the door. You can notify the elevator management department by ringing the alarm bell or calling the elevator, and it will be repaired by professionals.
The elevator suddenly falls and reacts quickly. The first one is

When the elevator falls, you should quickly press the buttons on each floor. In this way, when the emergency power supply starts, the elevator can stop and continue to fall. If there is a handle in the elevator, first hold the handle tightly with one hand, then the entire back and head are close to the inner wall of the elevator to fix the person's position to avoid falling and hurting. If there are no handles in the elevator, the hands will support the inner wall of the elevator, and the entire back and head will be close to the inner wall of the elevator to fix the body. Make your knees bent and use your knees to withstand heavy blow pressure.
Faulty elevator door open
When the elevator door is opened, be sure to make sure the car arrives and accurately align it before entering and exiting the elevator. In case you step on the air and fall into the elevator shaft. When the elevator door is closing, passengers outside should not use their hands, feet, etc. to prevent the door from closing. People in the elevator should not stretch their hands or feet or heads, and they should not place the items they carry in the gap to prevent the elevator door from closing.
6333 Elevator Emergency Rescue Platform As early as the beginning of this year, the Shenyang Elevator Safety Emergency Rescue and Disposal Center was officially put into use, and it is one of the first five pilot cities to be built in the country.

Data statistics and analysis from the beginning of the year to the end of October showed that the disposal center received 3,809 phone calls including elevator business consultation, and implemented a total of 269 elevator trapped rescues, and rescued a total of 499 trapped people. The average time for maintenance personnel to arrive at the site is 11.4 minutes, and the average time for rescue on site is 6.4 minutes. can basically rescue the trapped people within 20 minutes.

If a passenger is trapped in the elevator, if there is no response when the emergency call button is pressed, the intercom device is called and the maintenance unit phone is called without answering, can call the 24-hour service hotline "96333".
Summary of the results of the elevator safety supervision spot check in Shenyang City