1. How to generate oil fume in an integrated environmentally friendly furnace? In terms of the oil fume suction and discharge method, traditional range hoods absorb oil fume on the top of the furnace, while the current integrated furnaces use side fume down to deal with oil fume

2025/04/0913:44:36 home 1081

1. How to generate oil fume in integrated environmental protection furnace?

In terms of the oil fume suction and discharge method, the traditional range hood absorbs oil fume on the top of the furnace, while the current integrated furnaces are more of the side sucking and discharged to deal with oil fume problems.

The smoke exhaust pipe of the integrated furnace is under the machine. The oil fume enters the side fume purifier through the side fume, and then is discharged through the lower air outlet to achieve the effect of separation and inhalation of the oil fume.

waste oil flows naturally downwards and flows from top to bottom into the bottom oil collection tank, without contaminating the kitchen and stove.

suction hole is installed around the gas stove, and range hood is very close to the gas stove, so the oil smoke cannot diffuse around and is sucked into the smoke exhaust pipe. It is a zero-distance oil smoke, and even the chili is fried, it does not suffocate. Therefore, the fume purification rate of the integrated stove can reach more than 99%.

1. How to generate oil fume in an integrated environmentally friendly furnace? In terms of the oil fume suction and discharge method, traditional range hoods absorb oil fume on the top of the furnace, while the current integrated furnaces use side fume down to deal with oil fume  - DayDayNews

2. Analyze and maintain common causes of failure of integrated furnace

bad ignition

cause of failure/handling method:

1. Extend the ignition time (more air mixed into the air pipe)

2. Clean with cloth (ignition electrode oxidation)

3. Correct metal hose

4. Replace the ignition needle

0 automatically extinguish after ignition

0 Cause of failure/handling method:

1. Correct the position of the induction needle

2. If the center fire cover is removed from the fire and the induction needle cannot detect the heat source, adjust the damper to increase the air mixing

3. The motherboard is faulty (need to be sent to the repair point for repair)

pulse igniter is damaged

has gas odor

cause/handling method:

1. The metal hose is poorly connected or broken (valve needs to be replaced)

2. Gas sensitive head. The motherboard is damaged

flame Too small, yellow flame

cause/handling method:

1. The damper is too small, burning , oxygen is insufficient, and the damper needs to be adjusted to increase the air inlet

2. Ignition needle. The metal part of the induction needle is too dirty

1. How to generate oil fume in an integrated environmentally friendly furnace? In terms of the oil fume suction and discharge method, traditional range hoods absorb oil fume on the top of the furnace, while the current integrated furnaces use side fume down to deal with oil fume  - DayDayNews

Back-tempered

cause/handling method:

1. The fire hole is blocked or the cover is not covered

2. The gas composition fluctuates (the stove should be closed, the reason should be found)

poor smoking ability

l1

cause of fault/handling method:

1. The air duct is too long and there are too many elbows

2. The air outlet is blocked

3. The gear wind speed is abnormal (requires repair)

The fan does not turn

Cause of fault/handling method:

1. When motor thermal protector drops, the action of the motor thermal protector

2. The motor start capacitor is damaged

3. The motherboard is damaged or the power cord is off

1. How to generate oil fume in an integrated environmentally friendly furnace? In terms of the oil fume suction and discharge method, traditional range hoods absorb oil fume on the top of the furnace, while the current integrated furnaces use side fume down to deal with oil fume  - DayDayNews